Seitenansicht 43
0$7
$

5 If you need to remove a SIMM
before installing one, remove it as
follows; otherwise go to step 6.
»Note:
If all the SIMM connectors are
filled and you want to install more
memory, you have to exchange one
or more SIMMs for SIMMs with a
greater memory capacity.
a Using your thumbs, pull the
latches (one on each side of the
SIMM connector) outward.
b Tilt the SIMM backwards to a
45° angle away from the SIMM
connector.
c Lift the SIMM out.
6 Remove the new SIMM from its anti-static bag.
7 Insert the new SIMM into the
SIMM connector.
a Hold the SIMM at a 45° angle
to the controller board, with the
notch on the right side and the
bottom edge in the connector.
»Note:
You can insert a SIMM in
any SIMM connector as long
as DRAM0 and the SIMM
connector before the one
you’re installing are occupied.
...................................................
...................................................
...................................................
...................................................